Illumination value and design requirements of golf course lighting
1. Design requirements for golf course lighting
1. Lighting of the hitting area. Behind the main club hitting area, there must be at least 5m away from the hitting area set up a light pole. It is necessary use lamps with wide light distribution so that there is enough diffused light in the hitting area.
At the same time, decentralized installation of lamps is also considered. In order reduce or avoid the shadow of the hitter in the hitting zone.
2. The lighting equipment here can provide sufficient vertical lighting directly in front of the hitting area.
Therefore, most of the lights have be cast far forward, so that the flight trajecry and hit area of ??the hit ball have enough illumination, so that the hitter can use the line of sight track the ball's flight area and drop point range.
3. The arrangement of light poles and lamps should also consider sufficient horizontal illumination and uniformity. Minimize excessive brightness changes in illuminance.
4. The installation and projection direction of the lamps and lanterns should make the lamps and projection directions on the main channel follow the direction of the line of sight of the hitter avoid strong direct glare in the reverse direction. The lamps on the adjacent channels should prevent their direct light from becoming direct glare of the other side.
2. Recommended illuminance value for golf course lighting
With reference the illuminance standard values ??of golf courses and other stadiums, the recommended illuminance values ??of golf courses are as follows:
1. Illumination of the hitting area
(1) Horizontal illumination of the hitting area: The average horizontal illumination of the main hitting area should be above 150Lx;
(2) The vertical illuminance of the hitting area within 30m height:·
The average vertical illuminance behind the main pole area should be above 100Lx;
The average vertical illuminance at 100m in front of the hitting area should be above 300Lx;
The average vertical illuminance 200m in front of the hitting area should be above 150Lx.
2. Channel illumination
Within the tal length of the passage, whether it is horizontal or vertical illuminance, it is necessary provide good lighting conditions for this undulating hilly area. The required average level of illuminance should be above 120Lx.
The average vertical illuminance should be above 50Lx. The vertical illuminance is the average vertical illuminance on the cross section of the effective width within 30 m of the vertical height on the passage.
3. Illumination in the putting green area
Putting green areas should also have sufficient illumination. And should try reduce the human shadow caused by the hitter when hitting the ball in multiple directions in the area.
The average level of illuminance in this area should be 250Lx or more.
3. About the standard value of illuminance for sports lighting
The following is the standard value of illuminance for sports lighting in my country's national lighting standard "Civil Building Lighting Design Standard GBJ133-90".
Standard value of illuminance for sports lighting
Note:
1. Outdoor competitions of basketball and other events should be one level lower than the standard value of indoor competitions;
2. Other parts of the table tennis competition area should not be less than half of the tablep illumination;
3. The lighting design of the diving area should ensure that the illuminance in the direction of sight of the spectars and referees is not less than 200lx;
4. The viewing distance of football and hockey refers the distance from the last row of the audirium the sideline of the field.
4. Domestic and international and CIE sports building lighting regulations
Comparison table of illuminance standard values ??of sports buildings at home and abroad (unit: lx)
Shenzhen Lighting is a lamp manufacturer focusing on R&D and production of LED landscape lighting and outdoor lighting. It has 9 years of experience in military industry lighting services. It is located in Shenzhen Baoan. Its products cover: stadium lighting, LED sports lighting, stadium lights, LED stadium lights, High bay lights, high bay lights manufacturers, LED workshop lights, workshop LED lights, tunnel LED lights, LED tunnel lights, LED wer chandeliers, street lights, LED workshop lights, LED squares, lamps, LED lights, high pole lights, wer chandelier, LED Street lights, LED lamps, LED high pole lights, etc. For many years, our company has always put product quality in the first place. At present, the company has passed the ISO9001 international quality certification system, and the products have passed CE, ROHS, 3C and other domestic and international certifications and inspections. We insist on making cusmers feel free buy and use LED lights. Philosophy and mission, Lighting [Chongde Shangshan is the source of the original] look forward cooperating with you for a win-win situation.